 "generated_at": "2026-11-18T03:48:51.739Z",
 "note": "Candidates only. No OSM edit, changeset, import or pull request has been made. Financial and regulatory data are excluded.",
 "counts": {
  "operator": 6,
  "voltage": 3,
  "status_review": 1
 },
 "candidates": [
  {
   "kind": "operator",
   "osm_id": "osm:way/1006095235",
   "osm_url": "https://www.openstreetmap.org/way/1006095235",
   "current": null,
   "proposed": {
    "operator": "Oncor Electric Delivery"
   },
   "evidence": "https://interchange.puc.texas.gov/search/documents/?controlNumber=56006&itemNumber=330",
   "evidence_label": "PUCT monthly construction report for \"Sand Lake - Solstice 345 kV Line\" (filer)",
   "confidence": "medium: name match between OSM way and filed project name",
   "review": "Verify on current imagery and in the field record before editing; confirm the source's license allows use in OSM (ODbL); follow the OSM Organised Editing Guidelines; one changeset per topic with the source named."
  },
  {
   "kind": "operator",
   "osm_id": "osm:way/1006279910",
   "osm_url": "https://www.openstreetmap.org/way/1006279910",
   "current": null,
   "proposed": {
    "operator": "Oncor Electric Delivery"
   },
   "evidence": "https://interchange.puc.texas.gov/search/documents/?controlNumber=50421&itemNumber=38",
   "evidence_label": "PUCT monthly construction report for \"Riverton - Kyle Ranch 138 kV Line\" (filer)",
   "confidence": "medium: name match between OSM way and filed project name",
   "review": "Verify on current imagery and in the field record before editing; confirm the source's license allows use in OSM (ODbL); follow the OSM Organised Editing Guidelines; one changeset per topic with the source named."
  },
  {
   "kind": "operator",
   "osm_id": "osm:way/1454524506",
   "osm_url": "https://www.openstreetmap.org/way/1454524506",
   "current": null,
   "proposed": {
    "operator": "Oncor Electric Delivery"
   },
   "evidence": "https://interchange.puc.texas.gov/search/documents/?controlNumber=50421&itemNumber=38",
   "evidence_label": "PUCT monthly construction report for \"Kyle Ranch - Quarry Field 138 kV Line\" (filer)",
   "confidence": "medium: name match between OSM way and filed project name",
   "review": "Verify on current imagery and in the field record before editing; confirm the source's license allows use in OSM (ODbL); follow the OSM Organised Editing Guidelines; one changeset per topic with the source named."
  },
  {
   "kind": "operator",
   "osm_id": "osm:way/1454776036",
   "osm_url": "https://www.openstreetmap.org/way/1454776036",
   "current": null,
   "proposed": {
    "operator": "Oncor Electric Delivery"
   },
   "evidence": "https://interchange.puc.texas.gov/search/documents/?controlNumber=56006&itemNumber=330",
   "evidence_label": "PUCT monthly construction report for \"Bearkat - Longshore 345 kV Line\" (filer)",
   "confidence": "medium: name match between OSM way and filed project name",
   "review": "Verify on current imagery and in the field record before editing; confirm the source's license allows use in OSM (ODbL); follow the OSM Organised Editing Guidelines; one changeset per topic with the source named."
  },
  {
   "kind": "operator",
   "osm_id": "osm:way/1454524506",
   "osm_url": "https://www.openstreetmap.org/way/1454524506",
   "current": null,
   "proposed": {
    "operator": "Oncor Electric Delivery"
   },
   "evidence": "https://interchange.puc.texas.gov/search/documents/?controlNumber=56006&itemNumber=289",
   "evidence_label": "PUCT monthly construction report for \"Kyle Ranch - Quarry Field 138 kV Line (Modification of route approved in Docket No. 49302)\" (filer)",
   "confidence": "medium: name match between OSM way and filed project name",
   "review": "Verify on current imagery and in the field record before editing; confirm the source's license allows use in OSM (ODbL); follow the OSM Organised Editing Guidelines; one changeset per topic with the source named."
  },
  {
   "kind": "operator",
   "osm_id": "osm:way/1448341707",
   "osm_url": "https://www.openstreetmap.org/way/1448341707",
   "current": null,
   "proposed": {
    "operator": "AEP Texas"
   },
   "evidence": "https://interchange.puc.texas.gov/search/documents/?controlNumber=57477&itemNumber=176",
   "evidence_label": "PUCT monthly construction report for \"Angstrom - Naismith 345-kV T-Line\" (filer)",
   "confidence": "medium: name match between OSM way and filed project name",
   "review": "Verify on current imagery and in the field record before editing; confirm the source's license allows use in OSM (ODbL); follow the OSM Organised Editing Guidelines; one changeset per topic with the source named."
  },
  {
   "kind": "voltage",
   "osm_id": "osm:way/1467725741",
   "osm_url": "https://www.openstreetmap.org/way/1467725741",
   "current": null,
   "proposed": {
    "voltage": "138000"
   },
   "evidence": "https://www.ercot.com/mp/data-products/data-product-details?id=NP4-160-SG",
   "evidence_label": "ERCOT NP4-160-SG lists buses at substation code CARDINAL at 138 kV",
   "confidence": "low: name-only match; confirm it is the same facility",
   "review": "Verify on current imagery and in the field record before editing; confirm the source's license allows use in OSM (ODbL); follow the OSM Organised Editing Guidelines; one changeset per topic with the source named. ERCOT market data terms must be checked before any use in OSM."
  },
  {
   "kind": "voltage",
   "osm_id": "osm:way/466088494",
   "osm_url": "https://www.openstreetmap.org/way/466088494",
   "current": null,
   "proposed": {
    "voltage": "138000;69000"
   },
   "evidence": "https://www.ercot.com/mp/data-products/data-product-details?id=NP4-160-SG",
   "evidence_label": "ERCOT NP4-160-SG lists buses at substation code CARVER at 138, 69 kV",
   "confidence": "low: name-only match; confirm it is the same facility",
   "review": "Verify on current imagery and in the field record before editing; confirm the source's license allows use in OSM (ODbL); follow the OSM Organised Editing Guidelines; one changeset per topic with the source named. ERCOT market data terms must be checked before any use in OSM."
  },
  {
   "kind": "voltage",
   "osm_id": "osm:way/1394005084",
   "osm_url": "https://www.openstreetmap.org/way/1394005084",
   "current": null,
   "proposed": {
    "voltage": "138000"
   },
   "evidence": "https://www.ercot.com/mp/data-products/data-product-details?id=NP4-160-SG",
   "evidence_label": "ERCOT NP4-160-SG lists buses at substation code TOMATO at 138 kV",
   "confidence": "low: name-only match; confirm it is the same facility",
   "review": "Verify on current imagery and in the field record before editing; confirm the source's license allows use in OSM (ODbL); follow the OSM Organised Editing Guidelines; one changeset per topic with the source named. ERCOT market data terms must be checked before any use in OSM."
  },
  {
   "kind": "status_review",
   "osm_id": "osm:way/1448341707",
   "osm_url": "https://www.openstreetmap.org/way/1448341707",
   "current": {
    "power": "line"
   },
   "proposed": null,
   "evidence": "https://interchange.puc.texas.gov/search/documents/?controlNumber=57477&itemNumber=176",
   "evidence_label": "PUCT report: \"Angstrom - Naismith 345-kV T-Line\" is Construction underway (99% complete, 2025-06-13)",
   "confidence": "review only: the mapped way may be an older line on the same corridor",
   "review": "Check whether the mapped way is the new project (then power=construction may apply) or an existing line it replaces. Verify on current imagery and in the field record before editing; confirm the source's license allows use in OSM (ODbL); follow the OSM Organised Editing Guidelines; one changeset per topic with the source named."
  }
 ]
}